Joyous Oscillator

ZHA & ZIA Series 14 & 8 Pin DIP HCMOS/TTL

This oscillator device is designed to offer flexibity for a variety of applications including PLL & Telecommunications, in addition to others.


Electrical Specifications

Parameter Specification
Frequency Range 70.000MHz to 155.520MHz
Frequency Tolerance/Stability

All Measurements Inclusive of Operating Temperature Range, Supply Voltage & Load

±100ppm Maximum
±50ppm Maximum
±25ppm Maximum
±20ppm Maximum (0°C to +70°C Only)

Duty Cycle

50% ±10% (Measured at 1.4VDC with TTL Load or at 50% of waveform with HCMOS Load)

50% ±5% (Measured at 1.4VDC with TTL Load or HCMOS Load)

Operating Temperature Range 0°C to +70°C or
-40°C to +85°C
Storage Temperature Range -55°C to +125°C
Supply Voltage (VDD) 5.0VDC ±10%
Aging (at 25°C) ±5ppm/year Maximum
Load Drive Capability

10TTL or 50pF HCMOS Load

Input Current 50mA Maximum
Output Voltage Logic High (VOH) 2.4VDC Minimum with TTL Load
VDD-0.5VDC Minimum with HCMOS Load
Output Voltage Logic Low (VOL) 0.4VDC Maximum with TTL Load
0.5VDC Maximum with HCMOS Load
Rise Time / Fall Time

Measured over 0.4VDC to 2.4VDC with TTL Load or 20% to 80% of Waveform with HCMOS Load

3nSec Maximum

Tri-State Input Voltage (Pin 1)

+2.4VDC Minimum to Enable Output, +0.8VDC Maximum to Disable Output (High Impedance), No Connect to Enbale Output

Start Up Time 10mSec Maximum
Absolute Clock Jitter ±200pSec Maximum
One Sigma Clock Period Jitter ±50pSec Maximum

Mechanical Dimensions

14 Pin DIP Oscillator
14 Pin Dip

 


8 Pin DIP


Pin Connection

Pin #
( 14 Pin DIP / 8 Pin DIP)

Connection
1 / 1 No Connect or Tri-State
7 / 4 Ground / Case Ground
8 / 5 Frequency Output
14 / 8 Supply Voltage

Part Numbering Guide

ZHA 00 A 1 TS A - 20.000 M - G
                    Options
G = Gull Wing Leads
                  Options Prefix
                Frequency Unit of Measure
M = MHz
              Frequency
Entire Frequency with Decimal
            Frequency Prefix
          Supply Voltage
A = 5.0VDC ±10%
        Pin 1 Connection
NC = No Connect
TS = Tri-State
      Duty Cycle
1 = 50% ±10%
2 = 50% ±5%
    Operating Temperature Range
A = 0°C to +70°C
B = -40°C to +85°C
  Frequency Deviation
00 = ±100ppm
50 = ±50ppm
25 = ±25ppm
20 = ±20ppm
Series
ZHA = HCMOS/TTL 14 Pin DIP
ZIA = HCMOS/TTL 8 Pin DIP

 

Back to the Joyous Crystal Products Home Page


(714) 435-9530 ~ (714) 435-9705 FAX ~ anodyne@earthlink.net